Learn everything you need to know to prescribe, install and configure the Simon iO ecosystem.
Mechanisms
Simon Mizar Istanium LED urban decorative luminaire made of die-cast aluminium, with tangent cylindrical lateral fastening.
It provides necessary public lighting with maximum efficiency:
Simon has different own production centers, both in Spain and in other parts of the world. All of them are equipped with technical advances that allow us to comply with another of the principles that are the basis of our success: the performance of demanding tests and controls that guarantee the quality of all our products.
Configure the Mizar Istanium LED Luminaire to suit you
Simon's configurator provides high quality light reducing light pollution and energy consumption.
2N- with regulation without control line; self-regulation
The electronic equipment of the luminaire has a programmed timer that reduces the power by half after 4.5 hours from the moment of switching on.
2N+ Control line regulation
The electronic equipment has an input that is connected to the electrical cabinet. When the cabinet activates the control line voltage, the equipment delivers 100% of the nominal power to the Istanium LED module. When the cabinet disconnects the control line (0 volts), the equipment cuts power in half.
CAD Head flow regulation
The luminaire's electronic equipment adapts the supply current of the Istanium LED modules proportionally to the line input voltage. The head electrical cabinet must have a device that regulates the line voltage to reduce the lighting level of the appliance. This type of regulation is ideal for taking advantage of installations with cabinet equipment already installed.
1N without regulation
The electronic equipment delivers 100% of the power with no option to be regulated. If there is any fluctuation in the line voltage, the equipment compensates the supply current of the Istanium LED modules to maintain the luminous flux (input voltage from 208 to 277 Vac). Similarly, if the electrical cabinet has a flow regulation unit at the head, the unit will not regulate the lamp (an Istanium LED luminaire with CAD regulation is required).
1-10 Regulation governed by protocol 1-10V
The electronic equipment delivers the output power to the Istanium LED modules according to the level indicated by the 1-10 signal (normally delivered by a remote management device).
DALI regulation governed by DALI protocol
The electronic equipment delivers the output power to the Istanium LED modules according to the level indicated by the DALI signal (normally delivered by a remote management device).
IP65
Completely dustproof. Protected against water jets.
IP66
Completely dustproof. Protected against strong jets of water or heavy seas.
IK08
Protection against external mechanical shocks of 5 J of energy and 1.7 Kg/295 mm of mass and height of the impact piece.
Body
Die-cast aluminum
Fixation System
Galvanized and painted steel sheet
Closure system
Painted die-cast aluminum lever
Diffuser
Unbreakable Flat Clear Tempered Glass
Deck
Die-cast aluminum
UNE-EN 62031
LED modules for general lighting. Security requirements
UNE-EN 60598-1
luminaries. Part 1 : General requirements and tests
UNE-EN 60598-2-3
Public lighting luminaires. Part 2 : corresponding to the particular type of luminaire studied
UNE-EN 62493
Evaluation of lighting equipment with respect to human exposure to electromagnetic fields
UNE-EN 61000-2-3
Electromagnetic compatibility (EMC). Part 3-2 : Limits. Harmonic current emission limits (equipment with input current <= 16 A per phase).
UNE-EN 61000-3-3
Electromagnetic compatibility (EMC). Part 3-3 : Limits. Limitation of voltage variations, voltage fluctuations and flicker in public low voltage power supply networks for equipment with nominal current <= 16 A per phase and not subject to conditional connection.
UNE-EN 55015
Limitation of voltage variations, voltage fluctuations and flicker in public low voltage power supply networks for equipment with nominal current <= 16 A per phase and not subject to conditional connection.
UNE-EN 61547
General purpose lighting equipment. EMC immunity requirements.
UNE-EN 61347-2-13
Lamp control devices. Part 2-13: Particular rules for electronic control devices powered with direct current or alternating current for LED modules.
UNE-EN 62471:2009
Photobiological safety of lamps and devices that use lamps.
UNE-EN 50581
Technical documentation for the evaluation of electrical and electronic products with regard to the restriction of hazardous substances
4,000K
Neutral white light
3,000K
Warm white light
2,700K
Soft white light
XDL 2,200K
Extra warm white light.
APC
Amber turned into phosphorus.
Protection degree IK08 - IP66 - IP65
Class
Certificates CE - ENEC
Weight 12,75 kg
Colore temperaturas NDL 4.000 K, WDL 3.000 K, SDL 2.700 K, APC
Color rendering index >70
Upper hemisphere flow <1% (zonas E1)
LED Duration (L90 B10 a Ta=25 ºC y Tj=95 ºC) 100.000 h
Photometric distribution (Optics) RG/ RJ/ RA/ RE/ SA/ RF/ RW