Mechanisms
Simon Merak SYF Istanium LED® urban decorative luminaire made of die-cast aluminium, with post-top fastening by means of two Y-shaped arms.
It provides necessary public lighting with maximum energy efficiency:
Compact luminaire with a flat cover and an internal LED cooling system.
Lighting for a pedestrian street with a three-pin location that allows the use of SA optics and reducing units without losing comfort in the installation
Lighting for squares or gardens with an SA optic that allows creating uniform and soft lighting.
2N- with regulation without control line; self-regulation
The electronic equipment of the luminaire has a programmed timer that reduces the power by half after 4.5 hours from the moment of switching on.
2N+ Control line regulation
The electronic equipment has an input that is connected to the electrical cabinet. When the cabinet activates the control line voltage, the equipment delivers 100% of the nominal power to the Istanium LED module. When the cabinet disconnects the control line (0 volts), the equipment cuts power in half.
CAD Head flow regulation
The luminaire's electronic equipment adapts the supply current of the Istanium LED modules proportionally to the line input voltage. The head electrical cabinet must have a device that regulates the line voltage to reduce the lighting level of the appliance. This type of regulation is ideal for taking advantage of installations with cabinet equipment already installed.
1N without regulation
The electronic equipment delivers 100% of the power with no option to be regulated. If there is any fluctuation in the line voltage, the equipment compensates the supply current of the Istanium LED modules to maintain the luminous flux (input voltage from 208 to 277 Vac). Similarly, if the electrical cabinet has a flow regulation unit at the head, the unit will not regulate the lamp (an Istanium LED luminaire with CAD regulation is required).
1-10 Regulation governed by protocol 1-10V
The electronic equipment delivers the output power to the Istanium LED modules according to the level indicated by the 1-10 signal (normally delivered by a remote management device).
DALI regulation governed by DALI protocol
The electronic equipment delivers the output power to the Istanium LED modules according to the level indicated by the DALI signal (normally delivered by a remote management device).
IP66
Totally dustproof. Protected against strong jets of water or heavy seas.
IK09
Protection against external mechanical impact of 10 J of energy and 5 Kg/200 mm of mass and height of the hitting piece.
IK10
Protection against external mechanical impact of 20 J of energy and 5 Kg/400 mm of mass and height of the striking piece.
Body
Die-cast aluminum
Fixation System
Galvanized and painted steel sheet
Closure system
Painted die-cast aluminum lever
Diffuser
Unbreakable Flat Clear Tempered Glass
Deck
Die-cast aluminum
UNE-EN 60598-2-3
Public lighting devices. Part 2: corresponding to the particular type of luminaire studied.
UNE-EN 62493
Evaluation of lighting equipment with respect to human exposure to electromagnetic fields.
UNE-EN 61000-2-3
Electromagnetic compatibility (EMC). Part 3-2: Limits. Harmonic current emission limits (equipment with input current <= 16 A per phase).
UNE-EN 55015
Limits and methods of measurement of the characteristics linked to radioelectric disturbances of lighting and similar devices.
UNE-EN 61547
General purpose lighting equipment. EMC immunity requirements.
UNE-EN 50581
Technical documentation for the evaluation of electrical and electronic products with respect to the restriction of hazardous substances.
4,000K
Neutral white light
3,000K
Warm white light
2,700K
Soft white light
XDL 2,200K
Extra warm white light.
APC
Amber turned into phosphorus.
Protection degree IK10 - IK09 - IP66
Class
Certificates CE - ENEC
Weight 10 kg
Color temperatures NDL 4.000 K, WDL 3.000 K, SDL 2.700 K, APC
Color rendering index >70
Upper hemisphere flow <1% (zonas E1)
LED Duration (L90 B10 a Ta=25 ºC y Tj=95 ºC) 100.000 h
Photometric distribution (Optics) RG/ RJ/ RA/ RE/ SA/ RF/ RW