Simon Merak SYF

Simon Merak SYF

Simon Merak SYF Istanium LED® urban decorative luminaire made of die-cast aluminium, with post-top fastening by means of two Y-shaped arms.

It provides necessary public lighting with maximum energy efficiency:

 

  • Light flux > 3,550 lm
  • Efficiency up to 145 lm/W
  • Guaranteed thermal management
Properties
Pedestrian streets
Street
Roundabouts intersections
Garden park
Square
Commercial areas
Regulation

2N- with regulation without control line; self-regulation

The electronic equipment of the luminaire has a programmed timer that reduces the power by half after 4.5 hours from the moment of switching on.

 

2N+ Control line regulation

The electronic equipment has an input that is connected to the electrical cabinet. When the cabinet activates the control line voltage, the equipment delivers 100% of the nominal power to the Istanium LED module. When the cabinet disconnects the control line (0 volts), the equipment cuts power in half.

 

CAD Head flow regulation

The luminaire's electronic equipment adapts the supply current of the Istanium LED modules proportionally to the line input voltage. The head electrical cabinet must have a device that regulates the line voltage to reduce the lighting level of the appliance. This type of regulation is ideal for taking advantage of installations with cabinet equipment already installed.

 

1N without regulation

The electronic equipment delivers 100% of the power with no option to be regulated. If there is any fluctuation in the line voltage, the equipment compensates the supply current of the Istanium LED modules to maintain the luminous flux (input voltage from 208 to 277 Vac). Similarly, if the electrical cabinet has a flow regulation unit at the head, the unit will not regulate the lamp (an Istanium LED luminaire with CAD regulation is required).

 

1-10 Regulation governed by protocol 1-10V

The electronic equipment delivers the output power to the Istanium LED modules according to the level indicated by the 1-10 signal (normally delivered by a remote management device).

 

DALI regulation governed by DALI protocol

The electronic equipment delivers the output power to the Istanium LED modules according to the level indicated by the DALI signal (normally delivered by a remote management device).

Protection

IP66

Totally dustproof. Protected against strong jets of water or heavy seas.

 

IK09

Protection against external mechanical impact of 10 J of energy and 5 Kg/200 mm of mass and height of the hitting piece.

 

IK10

Protection against external mechanical impact of 20 J of energy and 5 Kg/400 mm of mass and height of the striking piece.

Materials and finishes

Body

Die-cast aluminum

 

Fixation System

Galvanized and painted steel sheet

 

Closure system

Painted die-cast aluminum lever

 

Diffuser

Unbreakable Flat Clear Tempered Glass

 

Deck

Die-cast aluminum

Regulation and certification

UNE-EN 60598-2-3

Public lighting devices. Part 2: corresponding to the particular type of luminaire studied.

 

UNE-EN 62493

Evaluation of lighting equipment with respect to human exposure to electromagnetic fields.

 

UNE-EN 61000-2-3

Electromagnetic compatibility (EMC). Part 3-2: Limits. Harmonic current emission limits (equipment with input current <= 16 A per phase).

 

UNE-EN 55015

Limits and methods of measurement of the characteristics linked to radioelectric disturbances of lighting and similar devices.

 

UNE-EN 61547

General purpose lighting equipment. EMC immunity requirements.

 

UNE-EN 50581

Technical documentation for the evaluation of electrical and electronic products with respect to the restriction of hazardous substances.

Color Temperature

4,000K

Neutral white light

 

3,000K

Warm white light

 

2,700K

Soft white light

 

XDL 2,200K

Extra warm white light.

 

APC

Amber turned into phosphorus.

Technical characteristics

Protection degree   IK10 - IK09 - IP66

Class

Certificates   CE - ENEC

Weight   10 kg

Color temperatures   NDL 4.000 K, WDL 3.000 K, SDL 2.700 K, APC

Color rendering index   >70

Upper hemisphere flow   <1% (zonas E1)

LED Duration (L90 B10 a Ta=25 ºC y Tj=95 ºC)   100.000 h

Photometric distribution (Optics)    RG/ RJ/ RA/ RE/ SA/ RF/ RW

 
Simon Urban Solutions Catalogue
 
Simon Merak SYF - Technical Sheet
 
Simon Merak - EU Declaration of Conformity