Simon Kuma

Simon Kuma

Simon Kuma Istanium LED lighting point, with die-cast aluminium light group and stainless steel support for the SS model, extruded aluminium in the AS model and painted galvanised steel in the DGCLAS model.

It provides necessary public lighting with maximum energy efficiency:

 

  • Light flux > 4,000 lm
  • Efficiency up to 138 lm/W
  • Guaranteed thermal management
Propierties
Street
Pedestrian streets
Parks and gardens
Square
Commercial areas

Configure the complete light point Simon Kuma

Simon's configurator provides high quality light reducing light pollution and energy consumption.

imatg_conf_kuma
Regulation

2N- with regulation without control line; self-regulation

The electronic equipment of the luminaire has a programmed timer that reduces the power by half after 4.5 hours from the moment of switching on.

 

2N+ Control line regulation

The electronic equipment has an input that is connected to the electrical cabinet. When the cabinet activates the control line voltage, the equipment delivers 100% of the nominal power to the Istanium LED module. When the cabinet disconnects the control line (0 volts), the equipment cuts power in half.

 

CAD Head flow regulation

The luminaire's electronic equipment adapts the supply current of the Istanium LED modules proportionally to the line input voltage. The head electrical cabinet must have a device that regulates the line voltage to reduce the lighting level of the appliance. This type of regulation is ideal for taking advantage of installations with cabinet equipment already installed.

 

1N without regulation

The electronic equipment delivers 100% of the power with no option to be regulated. If there is any fluctuation in the line voltage, the equipment compensates the supply current of the Istanium LED modules to maintain the luminous flux (input voltage from 208 to 277 Vac). Similarly, if the electrical cabinet has a flow regulation unit at the head, the unit will not regulate the lamp (an Istanium LED luminaire with CAD regulation is required).

 

1-10 Regulation governed by protocol 1-10V

The electronic equipment delivers the output power to the Istanium LED modules according to the level indicated by the 1-10 signal (normally delivered by a remote management device).

 

DALI regulation governed by DALI protocol

The electronic equipment delivers the output power to the Istanium LED modules according to the level indicated by the DALI signal (normally delivered by a remote management device).

Protection

IP66

Totally dustproof. Protected against strong jets of water or heavy seas.

 

IK08

Protection against external mechanical impact of 5 J of energy and 1.7 Kg/295 mm of mass and height of the striking piece.

Materials and Finishes

Shank

Painted galvanized steel, AISI 316 stainless steel or extorted aluminum.

 

Closing of the light group

Die-cast aluminum

 

Fixation System

Die-cast aluminum

 

Diffuser

High impact resistant transparent methacrylate or opal methacrylate

Regulation and certification

UNE-EN 62031

LED modules for general lighting. Security requirements

UNE-EN 60598-1

luminaries. Part 1 : General requirements and tests

 

UNE-EN 60598-2-3

Public lighting luminaires. Part 2 : corresponding to the particular type of luminaire studied

 

UNE-EN 62493

Evaluation of lighting equipment with respect to human exposure to electromagnetic fields

 

UNE-EN 61000-2-3

Electromagnetic compatibility (EMC). Part 3-2 : Limits. Harmonic current emission limits (equipment with input current <= 16 A per phase).

 

UNE-EN 61000-3-3

Electromagnetic compatibility (EMC). Part 3-3 : Limits. Limitation of voltage variations, voltage fluctuations and flicker in public low voltage power supply networks for equipment with nominal current <= 16 A per phase and not subject to conditional connection.

 

UNE-EN 55015

Limitation of voltage variations, voltage fluctuations and flicker in public low voltage power supply networks for equipment with nominal current <= 16 A per phase and not subject to conditional connection.

 

UNE-EN 61547

General purpose lighting equipment. EMC immunity requirements.

 

UNE-EN 61347-2-13

Lamp control devices. Part 2-13: Particular rules for electronic control devices powered with direct current or alternating current for LED modules.

 

UNE-EN 62471:2009

Photobiological safety of lamps and devices that use lamps.

 

UNE-EN 50581

Technical documentation for the evaluation of electrical and electronic products with regard to the restriction of hazardous substances

Color Temperature

4,000K

Neutral white light

 

3,000K

Warm white light

 

2,700K

Soft white light

 

XDL 2,200K

Extra warm white light.

 

APC

Amber turned into phosphorus.

Technical characteristics

Protection degree   IP44 - IP54 - IP66 - IK08

Class

Certifications   CE - ENEC

Weight   73 Kg, AS 38 Kg, SS 54 Kg

Color temperatures   NDL 4.000 K, WDL 3.000 K, SDL 2.700 K, APC

Color rendering index   >70

Upper hemisphere flow  <1% (zonas E1)

LED Duration (L90 B10 a Ta=25 ºC y Tj=95 ºC)   100.000 h

Photometric distribution (Optics)   RG/ RJ/ RA/ RE/ SA/ RF/ RW