RANGE

Simon Kelp Brazo Mural Merak

Simon KELP MERAK decorative wall arm, up to 1.5 m long, rectangular section, and lateral luminaire fastening.

b1_brazo_mural_merak
Properties

Configure the Kelp Wall Arm Merak Istanium LED luminaire to suit your needs

Simon’s configurator provides high-quality light to reduce light pollution and energy consumption.

imatge_configurador_brazo_960
Dimming

2N- Dimming without control line; self-dimming

The luminaire’s electronic control gear has a programmed timer that reduces the power by half 4.5 hours after it is turned on.

 

2N+ Dimming with control line

The electronic control gear has an input that connects it to the electrical cabinet. When the cabinet activates the voltage on the control line, the device delivers 100% of the nominal power to the Istanium LED module. When the cabinet disconnects the control line (0 volts), the device reduces the power by half.

 

CAD cabinet amplitude dimming

The luminaire’s electronic control gear adapts to the supply current of the Istanium LED modules, in proportion to the line input voltage. The amplitude dimming electrical cabinet must have a device that regulates the line voltage to reduce the light level of the luminaire. This dimming type is ideal to take advantage of installations with existing cabinet equipment installations.

 

1N without dimming

The electronic control gear delivers 100% of the power without a dimming option. If there is any fluctuation in the device’s line voltage, the supply current of the Istanium LED modules compensates to maintain the light flux (input voltage from 208 to 277 VAC). Likewise, if the electrical cabinet has a cabinet amplitude dimming device, the device will not dim the lamp (requires an Istanium LED luminaire with CAD dimming)

 

1-10 Dimming governed by 1-10V protocol

The electronic control gear delivers the output power to the Istanium LED modules according to the level indicated by the 1-10 signal (normally delivered by a remote management device).

 

DALI dimming regulated by DALI protocol

The electronic control gear delivers the output power to the Istanium LED modules according to the level indicated by the DALI signal (normally delivered by a remote management device).

Protection

IP66

Totally dust proof. Protected against strong water projections or against rough seas.

 

IK09

Protected against 10 Joules of external mechanical impact by an object with a mass of 5 Kg from a height of 200 mm.

 

IK10

Protected against 20 Joules of external mechanical impact by an object with a mass of 5 Kg from a height of 400 mm.

Materials and finishes

Body

Die-cast aluminium

 

Fastening system

Painted galvanised sheet steel

 

Closure system

Painted die-cast aluminium lever

 

Diffuser

Flat transparent shatter-proof tempered glass

 

Cover

Die-cast aluminium

Regulations and Certification

UNE-EN 60598-2-3

Public lighting luminaires. Part 2: corresponds to the specific type of luminaire being studied

 

UNE-EN 62493

Evaluation of lighting equipment related to human exposure to electromagnetic fields.

 

UNE-EN 61000-2-3

Electromagnetic compatibility (EMC). Part 3-2: Limits. Limits for harmonic current emissions (equipment with input current ≤ 16 A per phase).

 

UNE-EN 55015

Limitation and methods for measuring characteristics related to the radio-electrical disturbance of electrical lighting and similar equipment.

 

UNE-EN 61547

General-use lighting equipment. Requirements related to EMC immunity.

 

UNE-EN 50581

Technical documentation for the evaluation of electrical and electronic products regarding the restriction of dangerous substances.

Colour Temperature

4.000 K

Neutral white light

 

3.000 K

Warm white light

 

2.700 K

Soft white light

 

XDL 2.200 K

Extra warm white light.

 

APC

Phosphor-Converted Amber.

Technical Features

Protection level IP66 - IK09 - IK10

 

Class 

 

Certifications

 

Weight   10 kg

 

Color temperatures   NDL 4.000 K, WDL 3.000 K, SDL 2.700 K, APC

 

Colour rendering index   >70

 

Upper hemisphere light flux   <1% (zonas E1)

 

LED Duration (L90 B10 a Ta=25 ºC y Tj=95 ºC)   100.000 h

 

Photometric distribution (Optics)    RG/ RJ/ RA/ RE/ SA/ RF/ RW

Shape

Rectangular

Fastening

Lateral

Flange plate

4 gusset