Simon Kelp Altair

Simon Kelp Altair

Simon KELP ALTAIR decorative lighting point, up to 9 m high, with cylindrical shaft and lateral luminaire fastening on arms up to 0.75 m long.

Properties

Configure the Kelp Altair Istanium LED luminaire to suit your needs

Simon’s configurator provides high-quality light to reduce light pollution and energy consumption.

imatge_configurador_kelps_960
Dimming

2N- Dimming without control line; self-dimming

The luminaire’s electronic control gear has a programmed timer that reduces the power by half 4.5 hours after it is turned on.

 

1N without dimming

The electronic control gear delivers 100% of the power without a dimming option.

If there is any fluctuation in the device’s line voltage, the supply current of the Istanium LED modules compensates to maintain the light flux (input voltage from 208 to 277 VAC).

Likewise, if the electrical cabinet has a cabinet amplitude dimming device, the device will not dim the lamp (requires an Istanium LED luminaire with CAD dimming)

Protection

IP66

Totally dust proof. Protected against strong water projections or against rough seas.

 

IK09

Protected against 10 Joules of external mechanical impact by an object with a mass of 5 Kg from a height of 200 mm.

 

IK10

Protected against 20 Joules of external mechanical impact by an object with a mass of 5 Kg from a height of 400 mm.

Materials and finishes

Body

Die-cast aluminium

 

Cover

Die-cast aluminium

 

Closure system

Painted die-cast aluminium lever

 

Diffuser

Flat transparent shatter-proof tempered glass

 

Arm

Structural sheet steel

 

Arm trim

Die-cast aluminium

 

Shaft

Structural sheet steel

Regulations and Certification

UNE-EN 60598-1

Luminaires. Part 1: General requirements and tests.

 

UNE-EN 60598-2-3

Public lighting luminaires. Part 2: corresponds to the specific type of luminaire being studied

 

UNE-EN 62493

Evaluation of lighting equipment related to human exposure to electromagnetic fields.

 

UNE-EN 61000-2-3

Electromagnetic compatibility (EMC). Part 3-2: Limits. Limits for harmonic current emissions (equipment with input current ≤ 16 A per phase).

 

UNE-EN 61000-3-3

Electromagnetic compatibility (EMC). Part 3-3: Limits. Limitation of voltage changes and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase not subject to conditional connection.

 

UNE-EN 55015

Limitation and methods for measuring characteristics related to the radio-electrical disturbance of electrical lighting and similar equipment

 

UNE-EN 61547

General-use lighting equipment. Requirements related to EMC immunity.

 

UNE-EN 61347-2-13

Lamp control devices. Part 2-13: Particular requirements for electronic control devices powered by direct current or alternating current for LED modules.

 

UNE-EN 62471:2009

Photo-biological safety of lamps and lamp systems.

 

UNE-EN 40-5

Lighting columns and poles. Part 5: Requirements for steel lighting columns and poles.

Colour Temperature

4.000 K

Neutral white light

 

3.000 K

Warm white light

 

2.700 K

Soft white light

Shape

Cylindrical

Fastening

Lateral

Flange plate

4 gusset

 
Catálogo Soluciones Urbanas Nº 81
 
Simon Kelp - Ficha Técnica
 
Simon Kelp colores